The following manikins emphasise the importance of acquiring standardized universally accepted life-saving skills, which is mandatory for all doctors, especially anaesthesiologists, cardiologists, emergency room doctors, critical-care specialists, interns, and nursing staff.
The ACLS training programmes facilitate in recognizing and initiating early management of peri-arrest conditions and thereby help in preventing cardiac arrests.
breathing and pulse can not be detected. |
|
|
|
|
|
|
|
|
|
|
Features: |
|
External breast compression and artificial respiration: indicator light display, digital display device and sound prompting device |
|
Operation method: exercise operation |
|
Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse |
|
Working conditions: output power is 6V,the manostat apply to various external power or direct current of batteries. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features: |
|
This CPR Manikin is designed according to the AHA Guidelines for CPR and EEC. The operation standard: the AHA Guidelines for CPR and EEC. Issued by AHA (American Heart Association). This is the best & economical CPR Manikin available in the market! |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CPR Manikin Functional Features: |
|
Airway Simulating: The Compression indicated by Indicating lights, Counter and audio instruction |
|
When the compression position is right on the CPR Manikin, it will be indicated by the light, which is located in the central position in the chest, with green flash. And wrong position will be indicated by red flash. The compression times is indicated by the counter, which is located on the left side of the monitor. Some procedures will be guided by audio instruction. |
|
The ratio between compression and mouth-to-mouth ventilation on this CPR Manikin is : 30:2 |
|
The numbers of a whole circle: five circles of 30 times compression and 2 times ventilation. |
|
Report: A report is printed after practice. |
|
Mode: Training mode; Test mode. |
|
Pupil observation: From the beginning of the practice to the end, people can observe the change of the pupil vary from release to collect. |
|
To check the pulse of the cervical artery.# Power supply: 220V AC puts in through power adapter, and the output is 24V DC. The power supply for the Report Printer is 9V. |
|
|
|
|
|
|
|
|
|
|
|
|
Features: |
|
Washing, disinfection, hemostasia, enswathement, etc. |
|
Open fracture, truncation trauma |
|
Trauma evaluating modules: |
|
Facial burn: 1, 2,3 degree |
|
Laceration in forehead |
|
The wound in jaw |
|
Opened clavicular fracture and contusion wound on the chest |
|
he wound in abdomen with small intension evisceration |
|
Opened humerus fracture of right upper arm |
|
Opened fracture of right hand (including parenchyma laceration, fracture and
bone tissue exposure) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Gun wound in the right palm |
|
Opened fracture of right thighbone |
|
Compound femur fracture of left thigh |
|
Metal pricking wound in right thigh |
|
Opened tibia fracture of right leg |
|
Opened fracture of right foot with truncating trauma on small phalanx |
|
Burns in left forearm: 1, 2, 3 degree |
|
Truncating trauma on left thigh |
|
Closed tibia fracture of right leg and contusion wounds in left ankle and foot. |
|
|
|
|
|
|
|
|
|
|
|
|
Features: |
|
This Infant (Baby) CPR Training Manikin is specifically designed for professional Baby Cardiopulmonary Resuscitation training referring to American Heart Academy. |
|
Infant CPR Manikin Functional Features: |
|
Simulation of infant natural opening of the airway |
|
Baby-like inflations and compressions |
|
Realistic landmarks for compression position |
|
Brachial artery pulse, manual |
|
Indicator light of inhalation and compression |
|
Work frequency: 100 times per minute, or 120 times per minute (the latest international standard) |
|
Work condition: 220V electrical source passes through manostat, output 6V current |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Artificial Respiration: |
|
The digital indicator light bar of Skillguide shows the inhalation volume, compression depth. |
|
Manual Compression: |
|
If correct hand position compression, the green indicator light is activated. If incorrect compression, yellow indicator light is activated with warning prompt. |
|
Brachial Artery Pulse: |
|
The baby CPR manikin can simulate brachial artery pulse through squeeze bulb rhythmically. You can palpate it after squeezing the bulb rhythmically. |
|
Operation Frequency: |
|
When practice, should comply with the International First Aid Standard ratio 5:1, namely, 5 correct chest compressions and 1 correct artificial respiration. The compression frequency should be 120 times per minute or 100 times per minute |
|
|
|
|
|
|
|
|
|
|
|
|
Features: |
|
Accurate anatomical marks 2) Oral or nasal cavity intubation 3) It allows observing the suction position from side face so as to instruct correct method of the intubation skill. 4) Wrong operation, stomach inflation or laryngoscope compressing the teeth will activate warning prompting. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features: |
|
Realistic anatomy: tongue, cavum oris, pharynx, larynx, chordae vocals, trachea; |
|
Oral and nasal intubation; |
|
Lifelike material; |
|
Simuate head tilt to operate conveniently; |
|
Directly observe the expansion of lungs and stomach by insufflating air into the tube and stomach so as to verify if the tube position is right. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Imported Anatomical Models